Tektronix TDS 2012 digital storage oscilloscope

Direct From Site Clearance

Direct Site Clearance Price [?]
£ 750 (+ VAT)
Clearance ends
23 August 2017 14:00 GMT while stocks last
Buyer's Premium [?]
15% BP will be added to your invoice
Part of a Direct Site Clearance
Electronic Test Equipment
Stock No
NAB920
Model
TDS 2012
New or Used
Used (Second Hand)
Location
Our Central Warehouse, Aldridge, UK

Description

Tektronix TDS2000C Series digital storage oscilloscopes were introduced to enable users to achieve more in less time.

  1. Features incorporated as standard include USB connectivity, 16 automated measurements, limit testing, data logging and context-sensitive help.
  2. Compatible probes include:
  3. passive, TPP0101 ( 715-8733 ) TPP0201 ( 715-8743 ) P2220 ( 481-0823 ) P6101B ( 796-6708 ) P6015A ( 796-6702 ) P5100A ( 734-5013 );
  4. high voltage differential, P5200A ( 734-5029 );
  5. current, P6021A ( 781-0813 ) A621 ( 851-218 ) A622 ( 851-224 ) and current probe amplifiers TCPA300 ( 764-4391 ) TCPA400 ( 499-627 ).

TDS2000C Series

General purpose digital oscilloscopes for digital design and debug, education and training, manufacturing test and quality control, service and repair,

  • Full sample rate and full record length on all channels for accurate acquisition, all the time,
  • Highly portable, lightweight and compact form factor frees up valuable desk space
  • Convenient removable data storage via front panel USB flash drive port ,Plug-and-play PC connectivity via back panel USB device port,
  • Easy user interface with familiar, analogue-style controls, multipurpose knob, context-sensitive HELP and AUTORANGE function
  • AUTOSET button to detect and display the waveform, provides different views and displays up to four automatic measurements
  • Pulse width trigger speeds digital troubleshooting
  • External trigger input
  • Probe Check Wizard to quickly verify probes are calibrated and operating properly
  • Line-selectable video trigger permits triggering on a specific line of video to improve measurement productivity
  • Trigger signal frequency readout allows the measurement of a signal's frequency without the need for an output channel
  • 11 automatic measurements for fast, error-free measurements, ideal for repetitive tests
  • Fast Fourier Transform (FFT) (spectrum) display to analyse, characterise and troubleshoot circuits by viewing frequency and signal strength
  • Directly print screen images to any PictBridge compatible printer,Integrated security loop for theft protection

Features

  • 2.5 k point record length on all channels
  • Advanced triggers including Pulse Width trigger and line-selectable Video trigger
  • 16 automated measurements, and FFT analysis for simplified waveform analysis
  • Built-in waveform limit testing
  • Automated, extended data-logging feature
  • Autoset and signal auto-ranging
  • USB 2.0 Host Port on front panel for data storage, printing, and connecting a USB keyboard
  • USB 2.0 Device Port on rear panel for connection to PC or direct printing to a PictBridge®-compatible printer
  • Built-in context-sensitive Help
  • Probe check Wizard
  • Multiple-language user interface
  • 5.7in. (144 mm) Active TFT colour display
  • Small footprint and lightweight: 4.9in. (124mm) deep and 4.4lb. (2kg)
  • Record Length 2.5K points
  • Trigger type Edge (rise, fall), video, pulse width, glitch
  • Trigger modes Auto, normal, single 
  • Glitch Capture 12ns
  • Vertical sensitivity 2mv to 5v/div with calibrated fine adjustment
  • Vertical resolution/accuracy 8-bits / ±3%
  • Timebase range 5ns to 50 sec/div
  • Timebase accuracy 50ppm
  • Input impedance 1MΩ in parallel with 20pF
  • Acquisition modes Peak detect, sample, average, single